Indels in DNA Sequence Alignment
I wish to know about method to confirm that insertions shown in alignment are real and not artifacts of alignment.
Thanks Alka
alignment
• 1,461 views
•
link
written
by
dralka.vet
0
0 answers
No answers yet.
Log in to answer this question.
More posts like this
-
differences between trajectories in conditions with Monocle3 or other tools
written by Chironex 5hi, I ran the analysis of my dataset with monocle3 twice: the first on WT cells, the second on mutant cells. I wonder if there …
-
Diffrent between design co-Expression network with RNA-Seq data and micoarray data
written by askari.arezou94 3hello every one, I have a question about the difference between the design co-expression network with RNA-SEQ data and microarray data? I know that the …
-
Finding the correct sample size out of a list of genes
written by Bweil2 1I found the expression potential of 191 arabidopsis genes in different anatomical parts using Genevestigator. I need to determine if these genes are 'real' and …
-
How to deal with PCR artifacts in RNASeq data?
written by annen 3Hi everyone. I have an RNAseq dataset that I had done at a core facility (they did the library prep, sequencing, and initial analysis). At …
-
Per base statistics on an RNAseq bam file
written by tassa.saldi 0Hello, Does anyone know how I can create a file that gives me coverage, mismatches, insertions and deletions from an RNAseq bam file? Pysamstats is …
-
how to distinguish between artifacts and real indels?
written by genya35 5Hello, I’m working with multiple sequences (fasta format) of the same human gene (exons 2,3,4). Each sequence is about 5300 nucleotides long. When I import …
-
What does benchmark method exactly mean?
written by statfa 79Hi, My dictionary says, "benchmark means a level of quality that can be used as a standard when comparing other things". So a benchmark method …
-
Protein differences in HGVS format
written by M. Möller 4I have a bunch of protein sequences (~3.000) that I wish to compare with reference protein sequences, and I want the result in HGVS format. …
-
Solid And Hiseq
written by Liyf 3<p>Dear all: I have questions which wish your help. I read paper about exome sequencing and found that in cancer sequencing, there were very few …
-
Mummer To Viewable Alignment Format (Fasta Or Aln...)
written by Yannick Wurm 252<p>Hi, </p> <p>I'm aligning pairs of genomic scaffolds, looking for 1000bp-size insertions/deletions. Its easy to get a dotplot for an overview. It's also easy to …
Do sanger sequencing.
fin swimmer
The sequence obtained by sanger sequencing only and electropherogram files looks clean, sending samples again for sequencing will economically burden the lab. However, before reporting I want to be sure.
Regards
So we are talking about Sanger Sequencing data only? Is the insertion homozygous or heterozygous?
The sequence received is by Sanger sequencing and it is RNA virus gene.
Sanger is the usual method for confirming variants. If you want another method, think about something like real-time PCR or MLPA, with primers/probes targeting the inserted sequence. As an example, real-time PCR can accurately measure HER2 duplications in HER2-positive breast cancer (I know because I have developed assays for this).