Bowtie & Tophat
3
0
Entering edit mode
11.0 years ago
k.nirmalraman ★ 1.1k

My understanding to alignment tools are quite limited. Any suggestions are quite welcome. There are quite a lot of articles and questions already on this, but I am not able to find an answer in this context.

I am trying to understand what difference does it make to align the reads by using bowtie and tophat and cufflinks.

My data: Illumina short reads, single end reads . I am not interested in isoforms.

Currently I am using bowtie and aligning with 2/3 mismatches. (I am trimming away the barcodes, adapter sequences, also I am trimming the far end of sequences... At the end I have reads of length either 35 to 40). On an average I have about 78 - 80% of reads aligning to genome.

Do you see any limitations in directly using Bowtie over the other tools.

bowtie tophat cufflinks • 16k views
ADD COMMENT
0
Entering edit mode

./configure --prefix/opl/tophat_2.1.1 --with-boost=/opt/boost_1_62_0 .....im running this command to install tophat2bu its showing an error bash: ./configure: No such file or directory can any one plzzz give me a solution.

ADD REPLY
1
Entering edit mode

This is not an answer to this discussion and should be opened as a separate question. I moved this to a comment now.

You are in the wrong directory for that command. First cd into your downloaded directory.

Finally: tophat is superceded by hisat and therefore shouldn't be used anymore. Also STAR is a better alternative.

ADD REPLY
2
Entering edit mode
11.0 years ago

Use Tophat if your reference is the genome. Use Tophat if your reference is the transcriptome (e.g. a list of cDNA sequences, one per gen or one per isoform).

ADD COMMENT
2
Entering edit mode

So use tophat in both cases? Is that what you meant to write?

ADD REPLY
1
Entering edit mode
11.0 years ago

Bowtie is used for genomic reads alignment against the reference genome. Tophat is used for transcriptomic reads alignment against the reference genome and it uses bowtie in the first phase of alignment. But in addition to bowtie, tophat can also align reads that span exon-exon junctions. so you will get more read aligned against the reference genome if you use tophat for RNAseq data. Cufflinks is not an alignment tool. It is primarily used to calculate transcript abundance and abundance of different isoforms of the same gene.

Check the pages for bowtie, tophat and cufflink for more information.

ADD COMMENT
1
Entering edit mode
11.0 years ago
Geparada ★ 1.5k

If you use directly bowtie to align RNA-seq data to reference genome you won't map any read to splice junctions of the mRNAs. Tophat cat do the gaped alignments required to map reads to the splice junctions, but it's much more slower than bowtie.

As your reads are shorts, you probably get similar results with both programs due to the low probability that a short read has to map to a splice junction. So it's a good "quick n' dirty" approximation to start.

ADD COMMENT

Login before adding your answer.

Traffic: 2971 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6