This is a test version of Biostars. For the public version, visit https://www.biostars.org.
quantifying ribosomal content in Illumina libraries

Hi all,

Is there a standard tool people use to quantify the relative amounts of Ribosomal reads in RNA-seq libraries?

ribosomal

1 answer

Yes, you can use Picard CollectRnaseqmetrics.

Does everyone use the same set of Ribosomal intervals on hg19, or is there some variation between group?

Hmmm. This list doesn't seem to include 28S or 18S which I've read are the great majority of detected rRNAs

You're right. In GRCh37, it maps to an unplaced contig. However, using these regions does distinguish between good and bad ribodepletions. With a good depletion, we get 0-2% rRNA content, and I our failed experiments with a robotic protocol with a bad sometimes see as high as 30%. With TruSeq Stranded Total RNA with Ribo-Zero Gold, we consistently get 0-2%.

But you are right, these values should be interpreted as relative within a series, rather than estimates of absolute rRNA content.

Log in to answer this question.