This is a test version of Biostars. For the public version, visit https://www.biostars.org.
Low number of both surviving reads after trimming

Hi,

Trimming using Trimmomatic gave me these results:

code

trimmomatic PE -phred33 R1.fastq.gz R2.fastq.gz R1.paired.fastq.gz R1.unpaired.fastq.gz R2.paired.fastq.gz R2.unpaired.fastq.gz ILLUMINACLIP:adapter.fa:2:30:10 LEADING:20 TRAILING:20 SLIDINGWINDOW:4:15 MINLEN:25

output

Input Read Pairs: 429726444 Both Surviving: 160577915 (37.37%) Forward
Only Surviving: 268947096 (62.59%) Reverse Only Surviving: 91710 (0.02%) Dropped: 109723 (0.03%)

There was low percentage of both surviving reads, so, ?I performed trimming on R1 and R2.fastq separately, and the percentage of surviving reads in R1 and R2 each was over 99.9%. How can I interpret this trimming result?

Additionally, despite a both surviving rate is approximately 38%, the actual number of surviving leads is approximately 160M. I guess this is enough to continue with other processes, am i right?

Thanks!

trimmomatic trimming

Please edit your post and add the code parts again, this time use the 101010 code button and NOT the double quote button. The latter is used to cite a source verbatim and mangles monospaced code formatting.

code_formatting

Thanks, I modified.

I see that the code content was not added again, just the formatting modified. The output is still mangled. Compare it to the output you see on your screen and you'll notice that the post does not represent what you actually see.

Do you have a plot of adapter contamination for this data from FastQC? If you have a lot of adapter dimers, short inserts i.e. bad quality library then this would be an expected result.

Here is my fastqc, especially adapter content graph, before trimming(R1 and R2):

enter image description here

And this after trimming: enter image description here

Thank you for your response.

There was no particular reason of LEADING:20 and TRAILING:20, but I used the same parameters as I had used in previous projects which preferred to maintain high quality reads.

In fact, this data has many 'total sequences' because replicates are concatenated, so I wanted to extract highly reliable sequences and do downstream analysis. Therefore, even if both survival rates are approximately 38%, the actual number of surviving leads is approximately 160 million. What do you think about using the results after trimming to continue the rest of the process?

Thank you for your opinion.

I will try with lower LEADING and TRAILING bases. By the way, I tried to set keepBothReads:true through search and got the following result:

Input Read Pairs: 429726444 Both Surviving: 428299887 (99.67%) Forward Only Surviving: 1225124 (0.29%) Reverse Only Surviving: 173243 (0.04%) Dropped: 28190 (0.01%)

There are explanations for those parameters, but I still don't understand them clearly. ?Could you please explain a little more?

0 answers