What is the minimum system requement for oxford nanopore read assembly
What is the minimum system requirement for assembling long reads obtained from pacbio or oxford nanopore?
assembly
• 2,741 views
•
link
updated
by
Ram
4.5K
• |
written
by
nagendranp1991
0
0 answers
No answers yet.
Log in to answer this question.
More posts like this
-
SNPs calling using long-read whole-genome sequencing
written by YocelynGG 7Hi everyone, Has anyone here used long-read sequencing data (PacBio or Oxford Nanopore) for SNP discovery? Long-read sequencing data is well known for their power …
-
News: Assembling Genomes with Oxford Nanopore: A Hands-On Guide to Long-Read Sequencing
written by Physalia-courses 281Dear all, Are you working with long-read sequencing data or planning to dive into genome assembly using Oxford Nanopore Technologies? Join us this 29 September–2 …
-
Bambu on illumina short reads sequencing
written by Simone 0Hi all, I’m analyzing RNA-seq data generated with Illumina short reads from Singapore Consortium and I’m interested in using Bambu for transcript variant quantification. I …
-
What are best Long read simulator generating Oxford Nanopore Reads
written by Ashi 2Hi, I am using Badreads for simulating Oxford Nanopore long reads and then used BWA for mapping the short reads to these simulated long reads …
-
Raw Data from Oxford Nanopore Sequencing Technology
written by midox 29Hello, I need long reads rawdata generated by MinIon sequencer from Oxford nanopore technology? Can you help me? Thank you
-
Get aligment quality / identity from CRAM file (for PacBio and ONT data)
written by mschmid 18I have PacBio and Oxford Nanopore reads mapped to a reference sequence. Since I have very long reads I had to use CRAM format. Do …
-
fastQC for Oxford Nanopore reads
written by efratk 4Hi, I want to use fastQC for quality control checks on nanopore sequencing reads. When I ran fastQC it ran a long time without finishing …
-
Any tool designed to align short reads to long reads?
written by chongchu.cs 1Are there any tools specifically designed to align short reads to Pacbio or nanopore long reads?
-
PacBio data assembly with Celera
written by mhasa006 7<p>I have a set of PacBio long reads in fastq file. I want to assemble them in contigs. Which assembler will work well? If Celera …
-
Long read alignment
written by bdeonovic 21Does anyone have any recommendations for What aligners to use for long reads (e.g. Pac Bio, Oxford nanopore)? Currently I am using gmap, blast, lastz, …
I would say that the answer will depend on more what you are assembling (complexity of size or population)
For a 2 gb genome assembly?
How much data do you have?
We haven't sequenced yet. the organism have approximately 2 gb genome size.
In general, human genome can easily require a terabyte of RAM (or more) for de novo assembly so that should give you some idea. Having plenty of RAM would be a key. If your genome has repeats, ploidy (other then standard haploid/diploid) that would add to the complexity of this task.
Doing a
de novoassembly with only long reads (which are going to have a high error rate 10-15%) is probably not recommended for a genome of this size. You would want to throw in some short read coverage as well.thank you A cluster computing facility is not mandatory right?
Cluster computing facility is actually no help here. A typical cluster architecture is designed to provide lots of CPU nodes but cannot give you more memory than what a given node already has.
nagendranp1991 : This paper would be of interest: https://www.nature.com/articles/nbt.4060
Check the compute section for details on what they used.