how to exclude/include microarray chip based on pseudo-images?

Dear Biostars community,

I have got some affy microarray data to analyse, and some chips display artifacts, according to their residual pseudo-images. However, I do not know to what extent I should consider an array as acceptable based on the (size, shape...) artifact.

I have seen there are some methods for correction of such artifacts, either at probe level or at normalisation step, but I need a piece of advise to know If I should try to correct the chips or directly to discard them.

Thanks

affy microarray quality control

I don't think there are any hard rules for judging acceptability of an array based on its pseudo-image. If there's sign of extensive artifact or systematic pattern then the array should be discarded.
In general, if I can afford it, I prefer discarding problematic data over trying to find a mathematical/computational fix. If possible, it's better to redo an experiment than working with dodgy data.

enter image description here My problem to which extent of shape and size you would include an array in the analysis. For example, in this picture, there is a "drop" next to the border. In my opinion, it's too big, but when normalising the data, this array seems to be normal. However, there is another array, with a smaller "drop", which appears a bit abnormal, according to intensities distribution and RLE/NUSE. Then, the question is: if I discard the array with the small drop according to QC metrics, shouldn't I discard the one I show here, although it seems correct to the eyes of QC metrics?

Thanks