SPAdes set up parameters
How can I set up SPAdes to assemble contigs with a minimum length of 500 and filters out any contigs that are less than 500?
assembly
• 972 views
•
link
written
by
babdalhamid •
0 answers
No answers yet.
Log in to answer this question.
More posts like this
-
Why does MEGAHIT --min-contig-len 1 produce fewer long contigs than --min-contig-len 500 in a two-p…
written by Sachin •I'm running per-sample metagenomic assembly with MEGAHIT v1.2 on host-filtered paired-end reads, using a two-pass strategy: Pass 1: assemble paired-end reads (R1 + R2) <br> …
-
What is the recommended contig length to filter?
written by DNAngelI've run my samples through metaspades and am in the process of cleaning out some contigs that I don't need (i.e. obvious contamination). However I …
-
set the minimum contig length in spades
written by babdalhamid •Dear Sir/Madam: I have the following script for spades, quast, and prokka. It is working perfect. However, there are several contigs with less than 200 …
-
Filtering contigs by length during assembly?
written by n,nHello there guys I have a question that has been bothering me for a while since I can't find any clear documentation about it (in …
-
plasmid assemby from Illumina reads - help!
written by rebeccarenberg •I have some plasmids (purified) that were 1x150 sequenced on Illumnia. I am trying to assemble them, but am not having success using SPAdes or …
-
Criteria for filtering contigs after spades assembly
written by fhsantannaI have assembled a bacterial genome using spades. The coverage among the contigs is very heterogeneous, while some have more than 30 fold of coverage, …
-
interpretation Abyss stats
written by milanlove •i used Abyss to assemble some reads and after assembly, it give me stats like this: n:114915 min:500 n50:739 sum:2471869 it say me that minimum …
-
How to assemble contigs?
written by PaulHi have a new strain of bacterial genome for which sequencing was done using illumina. The sequence is a pair-end read for which I have …
-
understanding contig statistics
written by mary •I am trying to assemble a bacterial isolate genome from illumina miseq reads. the propose is to go forward for closing the complete genome and …
-
CD-HIT minimum sequence length
written by SwatchpuppyI have run cd-hit on my machine with a set of 1600 sequences, however the program says that only 1523 were read. I have managed …
Hello babdalhamid!
Questions similar to yours can already be found at:
We have closed your question to allow us to keep similar content in the same thread.
If you disagree with this please tell us why in a reply below. We'll be happy to talk about it.
Cheers!