Hi Devon,
Thanks for your insight. I will check with the people who did the bisulfite treatment about run 1.
Concerning the deduplication step, I had done some research on pubmed and people seem to perform the deduplication step in case of targeted capture Methyl-Seq :
Epigenetics 2015 - Agilent SureSelect Methyl-Seq kit, Illumina HiSeq2000, alignment and deduplication with Bismark. However, it is for mouse genome (mm9).
Epigenetics 2016 - SureSelectXT Methyl-Seq Target Enrichment System, HiSeq2000, alignement to human genome (hg19) and deduplication with Bismark.
Although the prep kits and sequencing platformq are different from those in my case, the general procedure seems to remain the same, which is why I decided to perform deduplication after alignment.
Please correct me if I'm wrong.