normalize ChIP-seq data by copy number variation
2
2
Entering edit mode
9.0 years ago
Ming Tommy Tang ★ 3.9k

Hi there,

I did some ChIP-seq in cancer cells. cancer genomes have copy number variations. Do you know any tools for normalizing ChIP-seq data for copy number variations and differential binding?

Thanks,
Ming

ChIP-Seq CNV • 4.0k views
ADD COMMENT
2
Entering edit mode
8.9 years ago
Ryan Dale 5.0k

I don't know of any tools, but as long as you have matched input controls for each, you could try doing CNV detection to remove those regions from analysis.

Alternatively, if you're interested in bound regions within CNV regions, whatever peak-caller you use might handle it via the IP vs input normalization. After peak-calling, and If you're doing ChIP-seq on proteins that have punctate binding sites, true peaks should have the characteristic strand bias, while CNVs would be larger and presumably not have this bias.

Differential binding will get tricky. You might need something like csaw, which uses the full edgeR GLM functionality, to explicitly model and control for the differences in input.

ADD COMMENT
0
Entering edit mode

Thank you for your comment. Yes, I will use input as a control. Just curious, does IgG control also work? I am doing chromatin marks. some are broad, I am planning to use diffReps http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0065598

ADD REPLY
1
Entering edit mode

The issue with IgG is that you're essentially pulling down noise, so there's a higher potential for things like sequencing bias and PCR bias to swamp any signal. Input seems to be a better control for open chromatin since you can sequence it better. For histone mods, you also might want something like a pan-H3 control.

Differential peak-callers seem to be at the same state peak-callers were 5 yrs ago. Sometimes you just have to try them all...

ADD REPLY
0
Entering edit mode
4.7 years ago

You can try HMCan(enter link description here) and HMCan-diff(enter link description here). Both are designed to handle copy number variation on ChIP-seq data in cancer samples.

HMCan is a peak caller, which can adjust copy number variation, GC bias and background noises. HMCan-diff is comparison tool based on HMCan, which can compare two ChIPed samples with copy numver variation, e.g., Histone modification ChIP-seq from cancer sample .vs. normal sample.

ADD COMMENT

Login before adding your answer.

Traffic: 2618 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6